ARX RECEIVER
Analog outputs available for both voltage and current signals. Maximum number of functions: 8 analog and 32 digital. Digital and analog inputs along with a CANopen output. Cabling via 32, 40 or 72-pin plug, connectors or multiple cable glands.
| 
   TECHINICAL DATA SHEET OF ARX RECEIVER  | 
 |
| 
   Power Supply  | 
  
   8-30 VDC 
  | 
 
| 
   Antenna  | 
  
   Dedicated antenna 1 or 5 meter  | 
 
| 
   Max number of outputs  | 
  
   8 analog
  (voltage)  
  | 
 
| 
   Rated current of STOP/Safety outputs  | 
  
   STP_1 = 2 A
  (30 VDC) 
  | 
 
| 
   Rated current of analog outputs  | 
  
   2 A (30 VDC)
  - PWM 
  | 
 
| 
   Rated current of digital outputs  | 
  
   2 A (30 VDC)  | 
 
| 
   Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061) 
  | 
  
   up to PL e, cat. 4 / SIL 3 
  | 
 
| 
   Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)  | 
  
   up to PL d, cat. 3 / SIL 2 
  | 
 
| 
   Protection degree 
  | 
  
   IP 66 (NEMA 4) 
  | 
 
| 
   Operating and storage temperature  | 
  
   operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷
  (+158 °F)  (-40 °F) ÷ (+185 °F) 
  | 
 
| 
   Cabling 
  | 
  
   Customizable – direct wiring on the solenoid valves; 32, 40 or 70-pin plug  | 
 
| 
   Dimensions 
  | 
  
   202 x 123 x 83
  mm 
  | 
 
| 
   Weight 
  | 
  
   1.2 kg 
  |