GRS for VRLA Batteries, push-in type This valve is an important part for all industrial VRLA batteries in GEL and AGM technology. The GRS CD with a central degassing function was especially developed for AGM automotive batteries. 

Main features:

  • IATA approved
  • Opening pressure can be calibrated between 100 - 300 mbar (1.45 – 4.35 psi)
  • All valves 100 % tested
  • Very small tolerances in opening and closing pressure
  • Reduce water loss in VRLA batteries and hence improve battery cycle life
Parameters :

Application

VRLA

Diameter mm

27

Type

push-in

Standard valve opening pressure

adjustable in production from 100 - 300 mbar

Closing pressure

> 80 mbar

Maximum operating temp.

80°C

Valve materials suitable for temp. range

-30°C to +80°C

Tightening torque in the battery lid

90 (+/-20) Newton-cm