CLS Standard

The ABERTAX® CLS - STANDARD is our basic version for monitoring the electrolyte level in a battery. The level probe is integrated in the LED housing, giving a steady GREEN signal, when electrolyte level is above the cell plates, and turning to flashing RED, when the electrolyte level is below the cell plates. 

Please follow the attached installation instruction. 

To install the CLS, you either drill a hole in the cell lid and use the Gauge Guard version for sealing and measuring the probe length, or you make use of the air agitation hole. For this installation you need the O-ring version.

  • Integrated LED
  • Integrated level probe
  • Gauge Guard or O-Ring
  • Various connector types
Technical parameters :

Input / Supply Voltage

12V (6 x 2V cells)

Max. Operating Volt. (12VDC nom.)

18VDC

Min. Operating Volt. (12VDC nom.)

10VDC

Current Consumption 12VDC

<20mA

Operational Temp. Range

30°C to +70°C

Temperature Sensor Range

n/a

Relative Humidity in Operation

95% no dew

Relative Altitude

Up to 2000m ASL

Protection class

IP65

Weight w. stand. version approx.

60g

Diameter probe (including seal)

5mm

Diameter hole for Gauge Guard

10mm (M10 drill)

Dim. Sensor head

30mm diameter, 20mm heights

Dim. Sensor bet. supply cable

27mm between cable grommets in housing. 31mm diameter of circular housing